Why a rule, not AI, decides when the tank is leaking

The deterministic leak and heat logic behind TankSaathi: how we turn tank-level readings into hours of water left and a sustained-loss alert, and why we label every assumption.

Team NicobarAndaman · Environmental Hacks, Bharat Builds Tour · Heat and Water track

The question a caretaker actually asks

A hostel caretaker doesn't want a graph. They want to know: "Will the tank last until the next supply?" And at 2 AM, they want to know if water is disappearing that shouldn't be. TankSaathi answers both with plain, deterministic TypeScript in a shared  core  package, covered by 124 unit tests and run inside AWS Lambda on every batch of readings.

From distance to hours left

The sensor (a labelled simulator in our build) reports the distance from the top of the tank to the water, in millimetres. From that:
  1. Tank geometry turns distance into litres, minus the water below the outlet that nobody can use.
  1. Outflow rate comes from the drop in level over recent readings, ignoring refills.
  1. Hours remaining divides usable litres by expected use, taken from an hourly demand profile for that kind of building.
  1. Heat adjustment: on a forecast of 40 °C or more we plan for about 20% more use. On a 42 °C day, our demo tank's estimate drops from about 16 hours to about 13.
That 20% is an assumption, drawn from public evidence that water use rises in heat waves, not a measured fact. The app labels it as one, and ASSUMPTIONS.md lists the sources. Each building can change it.

The sustained-loss rule

A leak looks like steady outflow at a time when the building should be quiet. Our rule checks the last three 15-minute windows (45 minutes). Every window must show loss well above what the profile expects for that hour:
  • Night (midnight to 5 AM): more than 3× the expected use.
  • Daytime: more than 2.5× the expected use.
  • And at least 150 litres an hour above expected, so a tiny baseline can't trip it.
Missing data never counts as a loss, and refill periods are left out of the rate, because use during a refill can't be observed. When all three windows agree, the ingest Lambda opens exactly one incident in a DynamoDB transaction and hands it to Step Functions.
In our demo, a stuck float valve loses about 220 litres an hour from 1 AM. After 45 minutes the rule fires once, with the tank at 20% and about three hours left. The app's chart shows the reason: night hours using more than three times the normal amount.

Why not let AI decide?

  • It has to be explainable. A caretaker should see why the alert fired: the numbers, the window, the threshold.
  • It has to be testable. Our tests check that 45 minutes of heavy night-time loss fires, that a shorter loss doesn't, that the normal morning peak and a refill aren't flagged, and that sparse data never decides. You can't pin a model's judgement down like that.
  • It has to be cheap and always on. The rule runs in milliseconds in Lambda for every reading.
We did plan to use Amazon Bedrock for one thing: rewriting the explanation in friendlier English and Hindi. Bedrock was blocked on our new account ("Operation not allowed"), so it stays behind a switch and the app uses standard text. The decision itself never depended on it.

Being honest about a hackathon build

We didn't have a real sensor or interviews with caretakers, so we said so: the readings come from a labelled simulator, the thresholds are configurable assumptions, and the Hindi needs a native speaker's review. The next step is a one-hostel pilot with an ESP32 and an ultrasonic sensor, then tuning the heat factor and night baseline from that building's own data.

Links

Any opinions in this article are those of the individual author and may not reflect the opinions of AWS.