When the simpler model wins: anomaly detection vs. classification on a real gas compressor

When the simpler model wins: anomaly detection vs. classification on a real gas compressor

How a 106,000-row SCADA dataset from a Shell gas compressor taught us that, with rare failures, "flag the unusual" beats "learn the fault" — and the three bugs we fixed getting there.

Most predictive-maintenance tutorials hand you a tidy dataset where failures are 10% of the rows and a gradient-boosted classifier nails an F1 of 0.9. Real industrial data doesn't look like that. We took an open predictive-maintenance skill  — a nine-phase workflow that goes from raw sensor data to validated baselines — and pointed it at a genuinely messy energy-sector dataset to see what would actually happen.
The short version: the supervised classifier everyone reaches for first was the wrong tool, and the data told us so in a way that's worth unpacking.

The dataset: a low-pressure gas compressor

Shell released a 10-minute-resolution SCADA export from a low-pressure gas compressor for the 2020 AIHack "Compressor Analytics" challenge. It's 106,710 rows across 362 sensor channels — roughly 110 temperatures, 92 pressures, 30 flow rates, a handful of speeds, plus level gauging and anonymized "unknown" tags. (Notably, no vibration channel, which is what you'd normally want on rotating equipment — a real-world constraint, not a choice.)
The data lives in the AIHack 2020 challenge repository:
(See the repository for the licensing terms.)
Before modeling anything, it helps to build a mental model of what's actually in the file:
Exploratory overview of the raw data. A top bar chart counts channels by type: Temperature 110, Anonymized 102, Pressure 92, Flow rate 30, Speed 14, Level 8, Time control 3, Gauging 3. Below it, five strip plots show the most failure-correlated channel from each physical family (temperature, pressure, flow, speed, level) z-scored across all 106,710 ten-minute samples, with the nine trips drawn as red bands.
What the data is made of (top) and what it looks like over time (bottom). Three things jump out. Instrumentation is lopsided — temperature and pressure are ~56% of all channels, and a full 102 channels (≈28%) are anonymized, so you're modeling partly blind. The signals are regime-switching, not smooth — the pressure trace steps between operating states, which is exactly the non-stationary behavior that trips up a model keyed to absolute values. And no single channel separates the failures: the most failure-correlated sensor in each family tops out at |corr| ≈ 0.12. The predictive signal, if it exists, is multivariate and subtle — which is the whole reason this is a hard problem and not a threshold on one gauge.
The labels are the hard part. There are just nine anomaly points marking equipment trips, and the authors are explicit that the definition is approximate. We turned each into a fault-imminent window by flagging the 24 raw timesteps (four hours) before each trip as positive. That gave us a binary machine_failure target — and a brutal class balance: 0.17% positive in train, 0.34% in test.
One design decision mattered more than any model choice: we built one labeled CSV pair that drives two formulations.
  • Classification uses machine_failure as a supervised target.
  • Anomaly detection ignores the label during training (fitting only on healthy rows) and uses it purely to score how well the model ranks anomalies.
Same data, same split (temporal 80/20, so we always predict the future from the past), two fundamentally different philosophies. That let us compare them head to head instead of arguing about it in the abstract.
One leakage trap worth calling out: the raw file ships with an original_index column that monotonically tracks time. Leave it in the feature set and your model "learns" that high indices precede trips — it's a clock, not a sensor. We drop it.

The result that flips the usual intuition

Here's the baseline scoreboard. Judge the rankers by AUROC (threshold- independent) rather than F1, because with 0.3% positives any fixed threshold is mostly measuring where you put the line, not how good the model is.
ModelTest AUROC
Isolation Forest (unsupervised anomaly detection)0.866
AutoGluon classifier (--rebalance)0.643
AutoGluon classifier (--smote)0.665
Horizontal bar chart of test AUROC for five models. The two unsupervised anomaly detectors (Temporal PCA 1-hour window at 0.876 and Isolation Forest at 0.866) sit well above the two supervised classifiers (SMOTE 0.665, rebalance 0.643); only the anomaly detectors clear the 0.75 quality gate.
Every unsupervised anomaly detector clears the 0.75 quality gate; neither supervised classifier does — even though the classifiers are the only models that got to see the failure labels during training.
The unsupervised model, which never sees a single failure label during training, ranks anomalies far better than the supervised classifier that's handed all 144 positive examples. That feels backwards until you think about what each model is being asked to do.
The classifier is trying to memorize what these particular nine trips looked like in the four hours beforehand. With only a few distinct failure events, it overfits their specific sensor fingerprints and then fails to recognize the unseen trips in the test set — different equipment state, different signature. The anomaly detector sidesteps the whole problem. It only needs to know what normal looks like, and normal is abundant (99.8% of the data). Any genuine trip is, almost by definition, a departure from normal — so it scores high regardless of whether it resembles a past failure.
When positives are sparse and each one is idiosyncratic, "learn normal and flag deviations" generalizes; "learn the failure" does not.

No, it isn't just the threshold

The obvious objection: the classifier's F1 is 0 because 0.5 is a silly threshold for a 0.3%-positive problem. Tune it and it'll be fine. We checked. For the anomaly detectors that objection is correct — tuning the threshold recovers a usable operating point. For the classifier it is not. Even an oracle threshold (one we cheated and tuned directly on the test labels, an optimistic ceiling you could never deploy) tops out at F1 ≈ 0.06. You can't threshold your way out of an AUROC of 0.64; the ranking itself isn't good enough. That's the real diagnosis, and it's only visible once you separate ranking quality from the thresholding decision.
ROC curves on the same test set and labels for three models. The Isolation Forest (AUROC 0.87) and Temporal PCA 1-hour (AUROC 0.88) curves bow steeply toward the top-left corner; the SMOTE classifier curve (AUROC 0.67) stays much closer to the random diagonal.
A threshold is just one point on these curves. The anomaly detectors bow toward the top-left — they rank almost any true trip above most normal timesteps. The classifier hugs the diagonal, so no choice of threshold turns it into a good alarm.
Rebalancing and SMOTE both nudged the classifier a little — SMOTE edged ahead on ranking (AUROC 0.665 vs 0.643) — but neither came close to the F1 ≥ 0.50 quality gate. More class-balancing cleverness wasn't going to save a model fighting the wrong fight.

Temporal context: a genuine trade-off, not a free win

Could we beat the point-wise Isolation Forest by giving the detector temporal context? We tried a sliding-window PCA reconstruction model at two window sizes:
ModelAUROCPoint-adjust F1 (tuned)False positives
Isolation Forest0.8660.00—
Temporal PCA, 1-hour window0.8760.0432,111
Temporal PCA, 2-hour window0.7380.241103
Two bar-chart panels over the same three anomaly-detection models. Left panel, ranking quality (AUROC): the 1-hour Temporal PCA window is highest at 0.876, the 2-hour window lowest at 0.738. Right panel, usable alarm (tuned point-adjust F1): the ranking flips — the 2-hour window is highest at 0.241 and the 1-hour window only 0.043.
The winner depends on the question. Best ranking (left) and best deployable alarm (right) are two different models — a tension a single headline metric hides.
No single model dominates. A short window barely beats Isolation Forest on ranking. A longer window actually loses ranking power — the wider subspace smears the sharp trip signatures — but produces a dramatically more usable alarm: F1 of 0.24 with 103 false positives instead of 2,111. For an operator who has to act on each alert, that trade is the whole ballgame, and it's the kind of thing a single headline metric hides.

The unglamorous part: three bugs between us and the results

Real work on real data means the tooling breaks in ways the happy path never exercised. Three fixes stood between us and the numbers above, and each is a decent cautionary tale:
  1. --rebalance crashed at evaluation. The classifier added a sample_weight column to the training frame but never told AutoGluon it was a weight — so the library treated it as a feature, then threw KeyError: ['sample_weight'] at evaluation time when the test frame didn't have it. The fix is one argument (sample_weight="sample_weight"), but the symptom pointed nowhere near the cause.
  2. SMOTE choked on missing values. ValueError: Input X contains NaN. SMOTE synthesizes new minority points by interpolating between neighbors, and you can't interpolate through a NaN. Real SCADA data is full of gaps, so the fix — median-impute before oversampling — is something any SMOTE-on-sensor-data pipeline needs.
  3. The temporal detector ran out of memory. StandardScaler quietly upcasts its output to float64. Flatten a 12-step sliding window over 362 features and you're holding several simultaneous ~3GB matrices (the windows, their PCA reconstruction, and the difference). On an 8GB box that's an instant OOM kill — with no traceback, because SIGKILL doesn't leave one. Keeping the scaled arrays in float32 (reconstruction error does not need double precision) halved the footprint and let the 2-hour window run at all.
None of these are exotic. They're exactly the failures you hit the first time a tool meets data that's wide, sparse, and full of holes — which is to say, real.

What to take away

  • Match the model to the label economics. Dozens of failure examples? A supervised classifier can work. A handful of idiosyncratic failures in a sea of normal operation? Unsupervised anomaly detection will usually generalize better, because it learns the thing you have lots of (normal) instead of the thing you barely have (failures).
  • Separate ranking from thresholding. An F1 of 0 can mean "bad model" or "bad threshold," and the fix is completely different. AUROC tells you which. Only tune the threshold once you've confirmed the ranking is worth operating on.
  • Pick the metric your operator lives with. AUROC says the 1-hour window is best; the person acknowledging alarms cares that the 2-hour window fires 103 times instead of 2,111. Report both.
  • Budget for the plumbing. Weight columns, missing values, and float64 memory blowups cost us more wall-clock than the modeling did. The messy parts are the work.
Any opinions in this article are those of the individual author and may not reflect the opinions of AWS.